DAMCOS液位傳感器探頭
點(diǎn)擊次數(shù):1883 發(fā)布時(shí)間:2016-3-17
DAMCOS液位傳感器探頭
type:MAS2600-H30-11-1-2P
Damcos液位傳感器MAS-2600,丹柯斯*,Tank contents transmitter,EMERSON Process Management,國(guó)外優(yōu)勢(shì)進(jìn)貨渠道一手貨源優(yōu)勢(shì)供應(yīng)。
MAS-2600變送器是一種基于電子發(fā)射器罐容量測(cè)量應(yīng)用而設(shè)計(jì)。
MAS的2600是一個(gè)2 - 線4-20毫安液位變送器經(jīng)由6芯通風(fēng)線連接的換能器和一個(gè)放大器組成的。
全焊接傳感器,坐落在鈦與鈦膜的是潛水(IP68)。
放大器安裝在海水性聚酯外殼(IP56)
-隔膜。
- 耐海水和化學(xué)品。
- 硅應(yīng)變儀傳感器。
- 電磁干擾,保護(hù)與現(xiàn)有發(fā)射器互換。
- 可編程從0.235 MH²O。
- 強(qiáng),重量輕,非常耐腐蝕耐
The MAS 2600 is manufactured in 4 programmable ranges from 0-3.5 mH²O to 0-35 mH²O, and available with a built-in Pt100 sensor。
供電范圍The Power Supply can vary from 14 to 33 VDC。
技術(shù)規(guī)格、參數(shù)
Programmable measuring ranges: Each transducer range programmable in 8
steps.
Accuracy: ± 0.25% F.S. at 20° C
TEB (Total Error Band): ±0.4% F.S. at 0 to +50°C
±2.0% F.S. at -20 to +80°C
Overload Capability: Min. 4 x transducer range with no changes in
calibration.
Burst Pressure: 6 x transducer range.
Built-in Temperature Sensor Pt100: Optional.
Diaphragm: Titanium
Sensor Housing: Titanium
Output Current: 4-20 mA DC, 2-wire system.
Power Supply: 14-33 VDC
Current Limiting:
Typically: 25 mA
Max.: 32 mA
Operating Temperature Ranges:
Transducer: -20 to +80°C (125 c for H-version)
Amplifier: -40 to + 85°C
Protection Class:
Transducer: IP 68
Amplifier: IP 56
Intrinsic Safety: EEx ia IIC T5 compliant. Max. 75 m cable
between transducer and transmitter amplifier.
Transducer ranges: 0-3.5 / 0-7 / 0-16 / 0-35 m H²O gauge
0.8 - 2.0/0.8-3.5 bar absolute
Programmable measuring ranges: Each transducer range programmable in 8
steps.
Accuracy: ± 0.25% F.S. at 20° C
TEB (Total Error Band): ±0.4% F.S. at 0 to +50°C
±2.0% F.S. at -20 to +80°C
Overload Capability: Min. 4 x transducer range with no changes in
calibration.
Burst Pressure: 6 x transducer range.
Built-in Temperature Sensor Pt100: Optional.
Diaphragm: Titanium
Sensor Housing: Titanium
Output Current: 4-20 mA DC, 2-wire system.
Power Supply: 14-33 VDC
Current Limiting:
Typically:
Max.:
25 mA
32 mA
Operating Temperature Ranges:
Transducer:
Amplifier:
-20 to +80°C (125 c for H-version)
-40 to + 85°C
Protection Class:
Transducer:
Amplifier:
IP 68
IP 56
Intrinsic Safety: EEx ia IIC T5 compliant. Max. 75 m cable
between transducer and transmitter amplifier.